Hydrogen-Deuterium Exchange Mass Spectrometry as an Emerging Analytical Tool for Stabilization and Formulation Development of Therapeutic Monoclonal Antibodies

Journal

JOURNAL OF PHARMACEUTICAL SCIENCES
Volume 104, Issue 2, Pages 327-345

Publisher

WILEY-BLACKWELL
DOI: 10.1002/jps.24224

Keywords

mass spectrometry; IgG antibody; monoclonal antibody; protein; formulation; protein aggregation; physical stability; physical characterization; molecular dynamics; chemical stability; excipients

Funding

  1. MedImmune (Gaithersburg, Maryland)
  2. Kansas Bioscience Authority (Olathe, Kansas)

Ask authors/readers for more resources

The dynamic nature of the structure of monoclonal antibodies (mAbs) can be probed at a resolution of 5-20 residues using hydrogen-deuterium exchange mass spectrometry (H/D-MS). Recent studies using H/D-MS have shown that distinct regions of IgG1 mAbs experience significant changes in backbone dynamics in response to specific physicochemical alterations, varying solution conditions, or exposure to different environmental stresses. Tracking such changes in local dynamics may therefore serve as a key analytical tool, not only to monitor stability changes, but also to design improved, and more stable formulations of therapeutic mAbs in pharmaceutical dosage forms. This review article describes the H/D-MS method as applied to the analysis of formulations containing mAbs and summarizes recent studies monitoring changes in mAb local dynamics in response to chemical modifications, physical degradation, and presence of stabilizing and destabilizing excipients. Furthermore, the nature of the local dynamics of a highly conserved peptide segment in the C(H)2 domain of IgG1 mAbs is reviewed, and the results are correlated with decreased pharmaceutical stability, supporting the identification of a common aggregation hotspot sequence in the F-c region of human IgG1 mAbs. In addition, unresolved challenges (and opportunities) in applying H/D-MS technology for stabilization and formulation development of mAbs are discussed. (c) 2014 Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 104:327-345, 2015

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available