4.6 Article

Multiplexed LC-MS/MS method for the simultaneous quantitation of three novel hepatitis C antivirals, daclatasvir, asunaprevir, and beclabuvir in human plasma

Journal

JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
Volume 107, Issue -, Pages 409-418

Publisher

ELSEVIER
DOI: 10.1016/j.jpba.2015.01.027

Keywords

LC-MS/MS; Daclatasvir; Asunaprevir; Beclabuvir (BMS-791325) and its metabolite; Human plasma; Pharmacokinetics

Ask authors/readers for more resources

Dual or triple combination regimens of novel hepatitis C direct-acting antivirals (DAA, daclatasvir, asunaprevir, or beclabuvir) provide high sustained virological response rates and reduced frequency of resistance compared to clinical monotherapy. To support pharmacokinetic (PR) assessments in clinical studies, a multiplexed liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantitation of daclatasvir, asunaprevir, beclabuvir (BMS-791325) and its active metabolite (BMS-794712) in human plasma was developed and validated. Human plasma samples were extracted with methyl-t-butyl ether followed by an LC-MS/MS analysis, which was conducted in a multiple reaction monitoring (MRM) mode. The lower limits of quantitation (LLOQ) were 1 ng/mL for daclatasvir, asunaprevir, and BMS-794712, and 2 ng/mL for beclabuvir. Intra-run precision (<= 4.5% CV), inter-run precision (<= 2.9% CV), and accuracy (+/- 5.3% deviation) based on different concentration levels (low, geometric mean, mid and high) of the quality control samples (QCs) provided evidence of the methods accuracy and precision. Selectivity and matrix effect on LC-MS/MS detection, stability in plasma, and potential interference of coadministered drugs (ribavirin and interferon) were all evaluated and the results were acceptable. Method reproducibility was demonstrated by the reanalysis of a portion of study samples. The cross-validation results for QCs demonstrated the equivalency between this method and two single-analyte methods which were previously validated for quantitation of daclatasvir in human plasma. This approach of using a multiplexed LC-MS/MS method for the simultaneous quantitation of three DAAs is time- and cost-effective, and can maintain good data quality in sample analysis. (C) 2015 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available