This study evaluated the accuracy of marginal and internal fit between the all-ceramic crowns manufactured by a conventional double-layer computer-aided design/computer-aided manufacturing (CAD/CAM) system and a single-layer system. Ten standardized crowns were fabricated from each of these two systems: conventional double-layer CAD/CAM system (Procera) and a single-layer system (Cerec 3D). The copings and completed crowns were seated on the abutments by a special device that facilitated uniform loading, and the marginal discrepancies were measured. Internal gaps were also measured using a low-viscosity silicone material. Marginal discrepancies of Procera copings were significantly smaller than those of Procera. crowns and Cerec 3D crowns (p<0.05), but Procera. crowns and Cerec 3D crowns did not differ significantly from each other (p>0.05). On internal gaps, Cerec 3D crowns showed significantly larger internal gaps than Procera copings and crowns (p<0.05). Within the limitations of this study, the single-layer system demonstrated acceptable marginal and internal fit.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available