4.7 Article

The corrosion behavior of Alloy 52 weld metal in cyclic hydrogenated and oxygenated water chemistry in high temperature aqueous environment

Journal

JOURNAL OF NUCLEAR MATERIALS
Volume 461, Issue -, Pages 10-21

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jnucmat.2015.02.033

Keywords

-

Ask authors/readers for more resources

The corrosion behavior of Alloy 52 weld metal in cyclic hydrogenated and oxygenated water chemistry in high temperature water is studied by in situ monitoring corrosion potential (E-corr), contact electric resistance (CER) and electrochemical impedance measurements (EIS), and ex situ scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) analysis. The E-corr and film resistance show large change when the environment is changed from hydrogenated water to oxygenated water and changeable with changing environment while the morphology and composition only show obvious distinction in the first cycle. The main factor controlling the electric/electrochemical properties of the oxide film is E-coro. (C) 2015 Elsevier B.V. All rights reserved.