4.3 Article

Fluorescent Particles in the Antibody Solution Result in False TF- and CD14-Positive Microparticles in Flow Cytometric Analysis

Journal

CYTOMETRY PART A
Volume 79A, Issue 12, Pages 990-999

Publisher

WILEY-BLACKWELL
DOI: 10.1002/cyto.a.21147

Keywords

antibody aggregates; microparticles; monocytes; phosphatidylserine; tissue factor

Ask authors/readers for more resources

Tissue factor (TF)-positive microparticles (MPs) are highly procoagulant, and linked to thrombosis in sepsis and cancer. MP-associated TF may be assayed by immunological or functional methods. Several reports have demonstrated discrepancies between TFprotein and TF-activity, which have been explained by antibody binding to encrypted'' or degraded forms of inactive TF-protein. Our goal was to evaluate the possible interference of fluorescent antibody aggregates in solutions containing antibodies against TF and CD14 in flow cytometric analysis. Using monocyte-derived microparticles (MPs) released from human monocytes, incubated with or without lipopolysaccharides (LPS) in vitro, we measured MP-associated TF-protein (flow cytometry) and TF-activity (clot formation assay). MPs released from monocytes exposed to LPS (1 ng mL(-1)) had similar to 14 times higher TF-activity than MPs originated from monocytes exposed to only culture medium. However, using untreated anti-TF antibodies (American Diagnostica and BD) in the flow cytometric analysis, MPs released from unstimulated monocytes had a similar number of TF-positive events as MPs secernated from LPS-stimulated monocytes [similar to 45,000 events mL 21 (American Diagnostica); similar to 15,000 events mL 21 (BD)]. These TF-positive events did not exert any TF-activity, and centrifugation (17,000g, 30 min, 4 degrees C) of the antibody solutions prior to use effectively removed the interfering fluorescent events. Removal of fluorescent interference, probably in the form of fluorescent antibody aggregates, from the antibody solutions by centrifugation is essential to prevent the occurrence of false positive flow cytometric events. The events can be mistaken as MP-associated TF-protein, and interpreted as a discrepancy between TF-protein and TF-activity. (C) 2011 International Society for Advancement of Cytometry

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available