OBJECT Multilevel long-segment lumbar fusion poses a high risk for future development of adjacent-segment degeneration (ASD). Creating a dynamic transition zone with an interspinous process device (IPD) proximal to the fusion has recently been applied as a method to reduce the occurrence of ASD. The authors report their experience with the Device for Intervertebral Assisted Motion (DIAM) implanted proximal to multilevel posterior lumbar interbody fusion (PLIF) in reducing the development of proximal ASD. METHODS This retrospective study reviewed 91 cases involving patients who underwent 2-level (L4-S1), 3-level (L3-S1), or 4-level (L2-S1) PLIF. In Group A (42 cases), the patients received PLIF only, while in Group B (49 cases), an interspinous process device, a DIAM implant, was put at the adjacent level proximal to the PLIF construct. Bone resection at the uppermost segment of the PLIF was equally limited in the 2 groups, with preservation of the upper portion of the spinous process/lamina and the attached supraspinous ligament. Outcome measures included a visual analog scale (VAS) for low-back pain and leg pain and the Oswestry Disability Index (ODI) for functional impairment. Anteroposterior and lateral flexion/extension radiographs were used to evaluate the fusion status, presence and patterns of ASD, and mobility of the DIAM-implanted segment. RESULTS Solid interbody fusion without implant failure was observed in all cases. Radiographic ASD occurred in 20 (48%) of Group A cases and 3(6%) of Group B cases (p < 0.001). Among the patients in whom ASD was identified, 9 in Group A and 3 in Group B were symptomatic; of these patients, 3 in Group A and 1 in Group B underwent a second surgery for severe symptomatic ASD. At 24 months after surgery, Group A patients fared worse than Group B, showing higher mean VAS and ODI scores due to symptoms related to ASD. At the final follow-up evaluations, as reoperations had been performed to treat symptomatic ASD in some patients, significant differences no longer existed between the 2 groups. In Group B, flexion/extension mobility at the DIAM-implanted segment was maintained in 35 patients and restricted or lost in 14 patients, 5 of whom had already lost segmental flexion/extension mobility before surgery. No patient in Group B developed ASD at the segment proximal to the DIAM implant. CONCLUSIONS Providing a dynamic transition zone with a DIAM implant placed immediately proximal to a multilevel PLIF construct was associated with a significant reduction in the occurrence of radiographic ASD, compared with PLIF alone. Given the relatively old age and more advanced degeneration in patients undergoing multilevel PLIF, this strategy appears to be effective in lowering the risk of clinical ASD and a second surgery subsequent to PLIF.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available