4.3 Article

Experimental investigation on mixed refrigerant Joule-Thomson cryocooler with flammable and non-flammable refrigerant mixtures

Journal

CRYOGENICS
Volume 50, Issue 10, Pages 653-659

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.cryogenics.2010.06.002

Keywords

Gas mixtures (B); Joule-Thomson cooler (E)

Ask authors/readers for more resources

The mixed refrigerant Joule-Thomson (MR J-T) cryocoolers have a wide application area covering the temperature range from 80 K to 200 K. The significant advantages of the system are simplicity of its design and working reliability with high level performance. The present paper discusses the experimental results of MR J-T cooler with different flammable and non-flammable mixture compositions. The work highlights the use of pressure-enthalpy and temperature-enthalpy diagrams for these mixtures to support the experimental results. A record lowest temperature of 65 K and a cooling capacity of 6 W at 80 K are obtained for a single stage MR J-T system starting at 300 K. Further, using a mixture of minimum flammable refrigerants, temperatures below 100 K is achieved. (C) 2010 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available