4.7 Article

Tribocorrosion behaviour of low temperature plasma carburised 316L stainless steel in 0.5 M NaCl solution

Journal

CORROSION SCIENCE
Volume 53, Issue 12, Pages 4131-4140

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.corsci.2011.08.021

Keywords

Stainless steel; Potentiostatic; Carburisation; Pitting corrosion

Ask authors/readers for more resources

Experiments have been carried out to study the tribocorrosion behaviour of low temperature plasma carburised 316L stainless steel under unidirectional sliding in 0.5 M NaCl solution, using a pin-on-disk tribometer integrated with a potentiostat for electrochemical control. It is found that the carburised layer exhibits much better resistance to material removal than the untreated specimen, particularly at anodic potentials. No corrosion pits are observed inside the wear track on the carburised specimen at anodic potentials as high as 750 mV (SCE). The results are discussed in terms of the relative contribution of wear and corrosion to overall material removal by tribocorrosion. (C) 2011 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available