4.7 Article

Corrosion behaviour of copper under chloride-containing thin electrolyte layer

Journal

CORROSION SCIENCE
Volume 53, Issue 10, Pages 3289-3298

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.corsci.2011.06.004

Keywords

Copper; EIS; Polarization; Atmospheric corrosion

Funding

  1. National Natural Science Foundation of China [50801056]
  2. Zhejiang Provincial Natural Science Foundation of China [Y4110074]
  3. Ministry of Education of China [200803351092]

Ask authors/readers for more resources

The corrosion behaviour of copper under chloride-containing thin electrolyte layers (TEL) was investigated using electrochemical impedance spectroscopy (EIS), cathodic polarization, linear polarization, SEM/EDS and XRD. The results indicate that the copper corrosion rate increases as TEL thickness decreases during the initial stages. After 192 h of immersion, the corrosion rate of copper under TEL in this order: 300 > 402 > 199 > bulk solution > 101 mu m. The corrosion behaviour is uniform under TEL and pitting is the primary corrosion type in the bulk solution. A corrosion model of the behaviour of copper under chloride-containing TEL is proposed. (C) 2011 Elsevier Ltd. All rights reserved.