4.7 Article

Tensile behavior of post-installed chemical anchors embedded to low strength concrete

Journal

CONSTRUCTION AND BUILDING MATERIALS
Volume 47, Issue -, Pages 861-866

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.conbuildmat.2013.05.032

Keywords

Chemical anchors; Axial behavior; Tensile capacity; Embedment depth; Free edge distance; Low-strength concrete

Ask authors/readers for more resources

In the scope of this paper, tensile capacities of post-installed chemical anchors embedded to 5.9 and 10.9 MPa concrete blocks are investigated. Pull-out tests are applied to 80 ductile steel bars (S420a). For the anchor diameters, 12, 16 and 20 mm are chosen. On the other hand, 10, 15 and 20 times the bar diameter are selected as free-edge distance and embedment depth for monotonic tensile loading tests. The results indicate that installation of anchors into low-strength concrete with sufficient embedment depth and free-edge distance is not unsafe as previously expected. To obtain ductile failure in low strength concrete, free-edge distance and embedment depth of minimum 15 times the anchor diameter should be required. Furthermore, a comparison of test results with AC! 318 capacities is done and it is observed that ACI 318 has quite an over-conservative approach for the tensile capacity of post-installed anchors when low-strength concrete is considered. (C) 2013 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available