4.7 Article

A home environment test battery for status assessment in patients with advanced Parkinson's disease

Journal

COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE
Volume 98, Issue 1, Pages 27-35

Publisher

ELSEVIER IRELAND LTD
DOI: 10.1016/j.cmpb.2009.08.001

Keywords

Test battery; Electronic diary; Self-assessment; Home environment; Motor test; Tapping; Spiral drawing; Movement disorder; Motor fluctuations; Parkinson's disease; Telemedicine

Funding

  1. Swedish Knowledge Foundation
  2. Solvay Pharmaceuticals
  3. Allschwil, Switzerland
  4. Nordforce Technology
  5. Stockholm Sweden

Ask authors/readers for more resources

A test battery for assessing patient state in advanced Parkinson's disease, consisting of self-assessments and motor tests, was constructed and implemented on a hand computer with touch screen in a telemedicine setting. The aim of this work was to construct an assessment device, applicable during motor fluctuations in the patient's home environment. Selection of self-assessment questions was based on questions from an e-diary, previously used in a clinical trial. Both un-cued and cued tapping tests and spiral drawing tests were designed for capturing upper limb stiffnes, slowness and involuntary movements. The patient interface gave an audible signal at scheduled response times and was locked otherwise. Data messages in an XML-format were sent from the hand unit to a central server for storage, processing and presentation. In tapping tests, speed and accuracy were calculated and in spiral tests, standard deviation of frequency filtered radial drawing velocity was calculated. An overall test score, combining repeated assessments of the different test items during a test period, was defined based on principal component analysis and linear regression. An evaluation with two pilot patients before and after receiving new types of treatments was performed. Compliance and usability was assessed in a clinical trial (65 patients with advanced Parkinson's disease) and correlations between different test items and internal consistency were investigated. The test battery could detect treatment effect in the two pilot patients, both in self-assessments, tapping tests' results and spiral scores. It had good patient compliance and acceptable usability according to nine nurses. Correlation analysis showed that tapping results provided different information as compared to diary responses. Internal consistency of the test battery was good and learning effects in the tapping tests were small. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available