3.9 Article

Computer-assisted planning and navigation improves cutting accuracy during simulated bone tumor surgery of the pelvis

Journal

COMPUTER AIDED SURGERY
Volume 18, Issue 1-2, Pages 19-26

Publisher

TAYLOR & FRANCIS LTD
DOI: 10.3109/10929088.2012.744096

Keywords

Pelvic bone tumor; safe margin; preoperative planning; intraoperative navigation; quantitative surgery; cutting accuracy

Categories

Funding

  1. Fonds National de la Recherche Scientifique (F.R.S.-FNRS Televie, Belgium) [7.4570.06]
  2. Fondation Belge contre le Cancer [SCIE 2006/20]

Ask authors/readers for more resources

Background: Resection of bone tumors within the pelvis requires good cutting accuracy to achieve satisfactory safe margins. Manually controlled bone cutting can result in serious errors, especially due to the complex three-dimensional geometry, limited visibility, and restricted working space of the pelvic bone. This experimental study investigated cutting accuracy during navigated and non-navigated simulated bone tumor cutting in the pelvis. Methods: A periacetabular tumor resection was simulated using a pelvic bone model. Twenty-three operators (10 senior and 13 junior surgeons) were asked to perform the tumor cutting, initially according to a freehand procedure and later with the aid of a navigation system. Before cutting, each operator used preoperative planning software to define four target planes around the tumor with a 10-mm desired safe margin. After cutting, the location and flatness of the cut planes were measured, as well as the achieved surgical margins and the time required for each cutting procedure. Results: The location of the cut planes with respect to the target planes was significantly improved by using the navigated cutting procedure, averaging 2.8 mm as compared to 11.2 mm for the freehand cutting procedure (p < 0.001). There was no intralesional tumor cutting when using the navigation system. The maximum difference between the achieved margins and the 10-mm desired safe margin was 6.5 mm with the navigated cutting process (compared to 13 mm with the freehand cutting process). Conclusions: Cutting accuracy during simulated bone cuts of the pelvis can be significantly improved by using a freehand process assisted by a navigation system. When fully validated with complementary in vivo studies, the planning and navigation-guided technologies that have been developed for the present study may improve bone cutting accuracy during pelvic tumor resection by providing clinically acceptable margins.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.9
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available