4.5 Article

Surface and intracardiac ECG for discriminating conduction disorders after CoreValve implantation

Journal

CLINICAL RESEARCH IN CARDIOLOGY
Volume 101, Issue 5, Pages 357-364

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00392-011-0400-6

Keywords

Conduction disorders; CoreValve; AV block; Pacemaker; Left bundle branch block; His bundle

Ask authors/readers for more resources

Background Transcatheter aortic valve implantation (TAVI) has been developed to minimize operative morbidity and mortality in high-risk symptomatic patients unfit for open surgery. With the proximity of the aortic valve annulus to the conduction system there is, however, an unknown risk of conduction disturbances necessitating monitoring and often cardiac pacing. Materials and methods We enrolled 50 consecutive patients from January 2007 to 2008 in our prospective evaluation of conduction disturbances measured by surface and intracardiac ECG recordings. Baseline parameters, procedural characteristics as well as twelve-lead surface ECG and intracardiac conduction times were revealed pre-interventionally, after TAVI and at 7-day follow-up. Results TAVI was performed successfully in all patients. During 7 days of follow-up the rate for first-degree AV block raised from 14% at baseline to 44% at day 7 (p < 0.001), while rates for type II second- and third-degree were 0 versus 8% (p < 0.001) and 0 versus 12% (p < 0.001), respectively. Similarly, the prevalence of new left bundle branch block (LBBB) rose from 2 to 54% (p < 0.001). Intracardiac measurements revealed a prolongation of both AH and HV interval from 123.7 +/- 41.6 to 136.6 +/- 40.5 ms (p < 0.001) and from 54.8 +/- 11.7 to 71.4 +/- 20.0 ms (p < 0.001), respectively. Pacemaker implantation at a mean follow-up of 4.8 +/- 1.2 days was subsequently performed in 23 patients (46%) due to complete AV block (12%) and type II second-degree AV block (8%) while another 13 patients (26%) received a pacemaker for the combination of new LBBB with marked HV prolongation. The high rate of first-degree AV block was primarily driven by an increase in HV interval. Conclusion Cardiac conduction disturbances were common in the early experience with CoreValve implantation necessitating close surveillance for at least 1 week.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available