4.5 Article

The role of bone debris in early healing adjacent to hydrophilic and hydrophobic implant surfaces in man

Journal

CLINICAL ORAL IMPLANTS RESEARCH
Volume 22, Issue 4, Pages 357-364

Publisher

WILEY-BLACKWELL
DOI: 10.1111/j.1600-0501.2010.02107.x

Keywords

bone debris; dental implants; human; osseointegration; SLA (R); SLActive (R); surface characteristics; wound healing

Funding

  1. ITI Foundation (ITI, Basel Switzerland) [371/04]
  2. Clinical Research Foundation (CRF) for the Promotion of Oral Health, Brienz, Switzerland [CRF 022/07]

Ask authors/readers for more resources

Objective To evaluate morphologically and morphometrically the sequential healing and osseointegration events at moderately rough implant surfaces with and without chemical modification. Particularly the role of bone debris in initiating bone formation was emphasized. Material and methods Solid, screw-type cylindrical titanium implants (SSI) (n=49), 4 mm long and 2.8 mm wide, with either chemically modified (SLActive (R)) or sandblasted and acid-etched (SLA (R)) surface configurations were surgically installed in the retromolar region of 28 human volunteers. After 7, 14, 28 and 42 days of submerged healing, the devices were retrieved with a trephine. Histologic ground sections were prepared and histomorphometrically analyzed. Linear measurements determined fractions of old bone (OBIC), new bone (NBIC), soft tissue (ST) and bone debris (BD) in contact with the SSI surfaces. Results Healing was uneventful at all installation sites. Sixty-one percent of all devices were suitable for morphometric analyses. All implant surfaces were partially coated with bone debris and new bone formation was observed as early as 7 days after installation. There was a gradual increase in NBIC, whereas OBIC, ST and BD progressively decreased over time. NBIC after 2 and 4 weeks was higher on SLActive (R) than on SLA (R) surfaces, albeit statistically not significant. The BD : ST ratio changed significantly from 7 to 42 days (from 50 : 50 to 10 : 90 for SLActive (R); from 38: 62 to 10 : 90 for SLA (R)) (Fisher's exact test, P < 0.01). Conclusion Both SLActive (R) and SLA (R) devices became progressively osseointegrated, while old bone on the device surface was gradually resorbed. The decrease in BD : ST ratio suggests that bone debris, created during implant installation and adhering to moderately rough surfaces, significantly contributed to the initiation of bone deposition and mediated the connection between the old bone and the new bone on the implant surface. To cite this article:Bosshardt DD, Salvi GE, Huynh-Ba G, Ivanovski S, Donos N, Lang, NP. The role of bone debris in early healing adjacent to hydrophilic and hydrophobic implant surfaces in man.Clin. Oral Impl. Res. 22, 2011; 357-364.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available