4.7 Article

MRI interactions of a fully implantable pressure monitoring device

Related references

Note: Only part of the references are listed.
Article Physiology

Chronic measurement of left ventricular pressure in freely moving rats

Ellyce Stehlin et al.

JOURNAL OF APPLIED PHYSIOLOGY (2013)

Article Radiology, Nuclear Medicine & Medical Imaging

Computational and experimental studies of an orthopedic implant: MRI-related heating at 1.5-T/64-MHz and 3-T/128-MHz

Yan Liu et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2013)

Article Radiology, Nuclear Medicine & Medical Imaging

Evaluation of MRI issues for a new neurological implant, the Sensor Reservoir

Frank G. Shellock et al.

MAGNETIC RESONANCE IMAGING (2013)

Article Biochemical Research Methods

A fully implantable telemetry system for the chronic monitoring of brain tissue oxygen in freely moving rats

David M. Russell et al.

JOURNAL OF NEUROSCIENCE METHODS (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

Assessment of MRI issues for the Argus II Retinal Prosthesis

James D. Weiland et al.

MAGNETIC RESONANCE IMAGING (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

Role of the Lead Structure in MRI-Induced Heating: In Vitro Measurements on 30 Commercial Pacemaker/Defibrillator Leads

Eugenio Mattei et al.

MAGNETIC RESONANCE IN MEDICINE (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

The dependence of radiofrequency induced pacemaker lead tip heating on the electrical conductivity of the medium at the lead tip

Deborah A. Langman et al.

MAGNETIC RESONANCE IN MEDICINE (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

Assessment of MRI Issues for a 3-T Immune Programmable CSF Shunt Valve

Frank G. Shellock et al.

AMERICAN JOURNAL OF ROENTGENOLOGY (2011)

Article Radiology, Nuclear Medicine & Medical Imaging

Measuring RF-Induced Currents Inside Implants: Impact of Device Configuration on MRI Safety of Cardiac Pacemaker Leads

Peter Nordbeck et al.

MAGNETIC RESONANCE IN MEDICINE (2009)

Article Engineering, Biomedical

Measurement, simulation and uncertainty assessment of implant heating during MRI

E. Neufeld et al.

PHYSICS IN MEDICINE AND BIOLOGY (2009)

Article Radiology, Nuclear Medicine & Medical Imaging

Artifacts in 3-T MRI: Physical background and reduction strategies

Olaf Dietrich et al.

EUROPEAN JOURNAL OF RADIOLOGY (2008)

Article Radiology, Nuclear Medicine & Medical Imaging

Spatial distribution of RF-induced E-fields and implant heating in MRI

Peter Nordbeck et al.

MAGNETIC RESONANCE IN MEDICINE (2008)

Article Medicine, Research & Experimental

Programmable infusion pump and catheter: Evaluation using 3-Tesla magnetic resonance imaging

Frank G. Shellock et al.

NEUROMODULATION (2008)

Article Radiology, Nuclear Medicine & Medical Imaging

Eddy-current induction in extended metallic parts as a source of considerable torsional moment

H Graf et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2006)

Article Radiology, Nuclear Medicine & Medical Imaging

Simple design changes to wires to substantially reduce MRI-induced heating at 1.5 T: implications for implanted leads

RW Gray et al.

MAGNETIC RESONANCE IMAGING (2005)

Article Engineering, Electrical & Electronic

MRI and implanted medical devices: Basic interactions with an emphasis on heating

JA Nyenhuis et al.

IEEE TRANSACTIONS ON DEVICE AND MATERIALS RELIABILITY (2005)

Article Radiology, Nuclear Medicine & Medical Imaging

Evaluation of specific absorption rate as a dosimeter of MRI-related implant heating

KB Baker et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2004)

Article Radiology, Nuclear Medicine & Medical Imaging

RF-induced temperature elevation along metallic wires in clinical magnetic resonance imaging: Influence of diameter and length

C Armenean et al.

MAGNETIC RESONANCE IN MEDICINE (2004)

Article Clinical Neurology

Monitoring and interpretation of intracranial pressure

M Czosnyka et al.

JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY (2004)

Article Radiology, Nuclear Medicine & Medical Imaging

Biomedical implants and devices: Assessment of magnetic field interactions with a 3.0-Tesla MR system

FG Shellock

JOURNAL OF MAGNETIC RESONANCE IMAGING (2002)

Article Radiology, Nuclear Medicine & Medical Imaging

Neurostimulation systems for deep brain stimulation: In vitro evaluation of magnetic resonance imaging-related heating at 1.5 tesla

AR Rezai et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2002)

Article Radiology, Nuclear Medicine & Medical Imaging

Investigation of the factors responsible for burns during MRI

MF Dempsey et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2001)

Article Radiology, Nuclear Medicine & Medical Imaging

Improved MR imaging for patients with metallic implants

AM Viano et al.

MAGNETIC RESONANCE IMAGING (2000)