4.7 Article

Circumferential Balloon-based Radiofrequency Ablation of Barrett's Esophagus With Dysplasia Can Be Simplified, yet Efficacy Maintained, by Omitting the Cleaning Phase

Journal

CLINICAL GASTROENTEROLOGY AND HEPATOLOGY
Volume 11, Issue 5, Pages 491-+

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.cgh.2012.12.005

Keywords

Comparison; Endoscopy; Radiofrequency Ablation; Clinical Trial

Funding

  1. BARRX Medical/Covidien
  2. Cook Medical
  3. Olympus Endoscopy
  4. AstraZeneca

Ask authors/readers for more resources

BACKGROUND & AIMS: The current procedure for circumferential balloon-based radiofrequency ablation (c-RFA) for the removal of dysplastic Barrett's esophagus (BE) is labor intensive, comprising 2 ablation passes with a cleaning step to remove debris from the ablation zone and electrode. We compared the safety and efficacy of 3 different c-RFA ablation regimens. METHODS: We performed a prospective trial of consecutive patients with flat-type BE with high-grade dysplasia. Fifty-seven patients (45 men; age, 64 +/- 15 y; 28 with prior endoscopic resection) were assigned randomly to groups that underwent c-RFA with a double application of RFA (12 J/cm(2)). The standard group received c-RFA, with device removal and cleaning, followed by c-RFA; the simple-with-cleaning group underwent c-RFA, with device cleaning without removal, followed by c-RFA; and the simple-no-cleaning group received 2 applications of c-RFA, and the device was not removed or cleaned. The primary outcome was surface regression of BE 3 months later, graded by 2 blinded expert endoscopists. Calculated sample size was 57 patients, based on a noninferiority design. RESULTS: Median BE surface regression at 3 months was 83% in the standard group, 78% in the simple-with-cleaning group, and 88% in the simple-no-cleaning group (P = .14). RF ablation time was 20 minutes (interquartile range [IQR], 18-25 min) for the standard group, 13 minutes (IQR, 11-15 min) for the simple-with-cleaning group, and 5 minutes (IQR, 5-9 min) for the simple-no-cleaning group (P < .01). The median number of introductions (RFA devices/endoscope) for the standard group was 7, vs 4 for the simple groups (P < .01). CONCLUSIONS: This randomized, prospective study suggests that c-RFA is easier and faster, but equally safe and effective, when the cleaning phase between ablations is omitted or simplified. Trialregister.nl, NTR 2495.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available