Sources of Variability in Measurements of Cardiac Troponin T in a Community-Based Sample: The Atherosclerosis Risk in Communities Study

Journal

CLINICAL CHEMISTRY
Volume 57, Issue 6, Pages 891-897

Publisher

AMER ASSOC CLINICAL CHEMISTRY
DOI: 10.1373/clinchem.2010.159350

Keywords

-

Funding

  1. National Heart, Lung, and Blood Institute [N01-HC-55015, N01-HC-55016, N01-HC-55018, N01-HC-55019, N01-HC-55020, N01-HC-55021, N01-HC-55022]

Ask authors/readers for more resources

BACKGROUND: Application of cardiac troponin T (cTnT) as a marker of myocyte damage requires knowledge of its measurement variability. Using a highly sensitive assay for measurement, we evaluated the long-term storage stability of plasma cTnT at -70 degrees C and the sources of cTnT variability. METHODS: Samples from the Atherosclerosis Risk in Communities study collected in 1996-1998 and 2005-2006 were assayed centrally to quantify variability in cTnT attributable to processing (replicates from same blood draw, n = 87), laboratory (replicates after freeze thaw, n = 29), short-term (n = 40) and long-term biological variation (repeat visit, n = 38), and degradation in frozen storage (n = 7677). RESULTS: Approximately 30% of this population-based cohort had cTnT concentrations below the detection limit (3 ng/L). Reliability coefficients for all paired comparisons exceeded 0.93 except for samples drawn 8 years apart (r = 0.36). Sources of cTnT variation (as CVs) were: laboratory, 2.1% and 11.2% in those with and without heart failure, respectively; processing, 18.3%; biological, 16.6% at 6 weeks and 48.4% at 8 years. The reference change value at 6 weeks (68.5%) indicated that 4 samples are needed to determine a homeostatic set point within +/- 25%. The estimated cTnT degradation rate over the first year in long-term frozen storage was 0.36 ng/L per year. CONCLUSIONS: cTnT was detectable in approximately 70% of community-dwelling middle-aged study participants and stable in -70 degrees C storage. The variability in cTnT attributable to 1 freeze-thaw cycle is of small magnitude. The observed high laboratory and intraindividual (biological) reliability of cTnT support its use for population-based research, and in clinical settings that rely on classification and serial measurements. (C) 2011 American Association for Clinical Chemistry

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available