4.3 Article

Relative stability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysis

Journal

CLINICAL BIOMECHANICS
Volume 24, Issue 2, Pages 203-209

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.clinbiomech.2008.11.002

Keywords

Locked plating; Stiffness; Strength; Diaphysis; Osteoporotic bone

Funding

  1. Legacy Foundation and NIH/NIAMS [R21 AR053611]

Ask authors/readers for more resources

Background: This study investigated the stiffness and strength of bridge plating with uni-cortical and bicortical locking plate constructs relative to a conventional, non-locked construct in the osteoporotic femoral diaphysis. Methods: Four bridge plating configurations were applied to a validated model of the osteoporotic femoral diaphysis. A non-locked conventional configuration served as baseline. Locked configurations included bi-cortical locked plating, uni-cortical locked plating and mix-mode locked plating, which combined uni and bi-cortical locking screws. For all configurations, an 11-hole plate was applied with 4.5-mm screws placed in the 1st, 3rd, and 5th plate hole. Five specimens of each configuration were dynamically loaded until failure in torsion, axial compression, and bending to determine construct stiffness, strength and failure modes. Findings: In torsion and bending, locked plating constructs provided a significantly lower stiffness and strength than the conventional construct. The uni-cortical locked construct was 69% weaker (P < 0.001) in torsion than the conventional construct, but its torsional strength improved 73% (P < 0.001) by adding one bi-cortical locked screw. In axial compression, construct stiffness varied by less than 10% between the four groups. However, the bi-cortical and mixed-mode locked constructs provided a significant increase in strength of 12% (P = 0.001) and 11 % (P = 0.002), respectively, compared to the conventional construct. Interpretations: Locked plating in the osteoporotic diaphysis can improve fixation strength under axial loading, but may reduce fixation strength in bending and torsion compared to conventional plating. Adding one bi-cortical locked screw to an otherwise uni-cortical construct is recommended to improve torsional strength. (C) 2008 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available