4.6 Article

Validation of 3D Echocardiographic Assessment of Left Ventricular Volumes, Mass, and Ejection Fraction in Neonates and Infants With Congenital Heart Disease A Comparison Study With Cardiac MRI

Journal

CIRCULATION-CARDIOVASCULAR IMAGING
Volume 3, Issue 6, Pages 735-742

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/CIRCIMAGING.109.928663

Keywords

echocardiography three-dimensional; infant; heart diseases; ventricles; magnetic resonance imaging

Funding

  1. Light Harvest Foundation
  2. Samantha's Harvest Foundation

Ask authors/readers for more resources

Background-Quantitative assessment and validation of left ventricular (LV) volumes and mass in neonates and infants with complex congenital heart disease (CHD) is important for clinical management but has not been undertaken. We compared matrix-array 3D echocardiography (3D echo) measurements of volumes, mass, and ejection fraction (EF) with those measured by cardiac MRI in young patients with CHD and small LVs because of either young age or LV hypoplasia. Methods and Results-Thirty-five patients aged <4 years (median, 0.8 years) undergoing MRI were prospectively enrolled. Three-dimensional echo was acquired immediately after MRI, and volume, mass, and EF measurements, using summation of discs methodology, were compared with MRI. Three-dimensional echo end-diastolic volume (24.4 +/- 15.7 versus 24.8 +/- 46.4 mL; P=0.01; intraclass correlation coefficient [ICC], 0.96) and end-systolic volume (12.3 +/- 8.6 versus 9.6 +/- 6.8 mL; P<0.001; ICC, 0.90) correlated with MRI with small mean differences (-0.49 mL [P=0.6] and 2.7 mL [P=0.001], respectively). Three-dimensional echo EF was smaller than MRI by 9.3% (P<0.001), and 3D echo LV mass measurements were comparable to MRI (17.3 +/- 10.3 versus 17.6 +/- 12 g; P<0.77; ICC, 0.93), with a small mean difference (1.1 g; P=0.28). There was good intra-and interobserver reliability for all measurements. Conclusions-In neonates and infants with CHD and small LVs (age appropriate or hypoplastic), matrix-array 3D echo measurements of mass and volumes compare well with MRI, providing an important modality for ventricular size and performance analysis in these patients, particularly in those with left-side heart obstructive lesions. (Circ Cardiovasc Imaging. 2010; 3: 735-742.)

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available