4.5 Article

Cardiac Dysfunction and Prolonged Hemodynamic Deterioration After Implantable Cardioverter-Defibrillator Shock in Patients With Systolic Heart Failure

Journal

CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY
Volume 5, Issue 5, Pages 898-905

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/CIRCEP.111.970285

Keywords

echocardiography; hemodynamics; implanted cardioverter defibrillators; ventricular fibrillation; cardiac function

Funding

  1. Grants-in-Aid for Scientific Research [23300172] Funding Source: KAKEN

Ask authors/readers for more resources

Background-We investigated the acute effects of implantable cardioverter-defibrillator shock on myocardium, cardiac function, and hemodynamics in relation to left ventricular systolic function. Methods and Results-We studied 50 patients who underwent implantable cardioverter-defibrillator implantation and defibrillation threshold (DFT) testing: 25 patients with left ventricular ejection fraction (LVEF) >= 45% and 25 patients with LVEF <45%. We measured cardiac biomarkers (creatine kinase, creatine kinase-MB, myoglobin, cardiac troponin T and I, and N-terminal probrain natriuretic peptide). Left ventricular relaxation was assessed by global longitudinal strain rate during the isovolumetric relaxation period using speckle-tracking echocardiography. Blood sampling and echocardiography were performed before, immediately after, and 5 minutes and 4 hours after DFT testing. Mean arterial pressure was measured directly during DFT testing. Cardiac biomarkers showed no significant changes in either group. LVEF was decreased until 5 minutes after DFT testing and had recovered to the baseline at 4 hours in the group with reduced LVEF (P<0.001), whereas LVEF reduction was not observed in the group with preserved LVEF (P=0.637). Global isovolumetric relaxation period was decreased until 5 minutes after DFT testing and had recovered to the baseline at 4 hours in both groups (preserved LVEF: 0.39 +/- 0.14 versus 0.23 +/- 0.13* versus 0.23 +/- 0.13* versus 0.40 +/- 0.13 s-1, *P<0.001 versus baseline; reduced LVEF: 0.15 +/- 0.05 versus 0.08 +/- 0.04 dagger versus 0.09 +/- 0.04 dagger versus 0.15 +/- 0.05 s(-1), dagger P<0.001 versus baseline, repeated-measures ANOVA). Time to recovery of mean arterial pressure to the baseline was prolonged in the group with reduced LVEF (P<0.001). Conclusions-Implantable cardioverter-defibrillator shock transiently impairs cardiac function and hemodynamics especially in patients with systolic dysfunction, although significant tissue injury is not observed. (Circ Arrhythm Electrophysiol. 2012;5:898-905.)

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available