4.5 Article

Endocardial Unipolar Voltage Mapping to Detect Epicardial Ventricular Tachycardia Substrate in Patients With Nonischemic Left Ventricular Cardiomyopathy

Journal

CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY
Volume 4, Issue 1, Pages 49-55

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/CIRCEP.110.959957

Keywords

catheter ablation; ventricular tachycardia; electrophysiology mapping; cardiomyopathy

Funding

  1. National Institutes of Health [K23 EB006481]

Ask authors/readers for more resources

Background-Patients with nonischemic left ventricular cardiomyopathy (LVCM) and ventricular tachycardia (V-T) have complex 3-dimensional substrate with variable involvement of the endocardium (ENDO) and epicardium (EPI). The purpose of this study was to determine whether ENDO unipolar (UNI) mapping with a larger electric field of view could identify EPI low bipolar (BIP) voltage regions in patients with LVCM undergoing V-T ablation. Methods and Results-The reference value for normal ENDO unipolar voltage was determined from 6 patients without structural heart disease. Consecutive patients undergoing VT ablation over an 8-year period with detailed (> 100 points) LV ENDO and EPI mapping and normal LV ENDO BIP voltage were identified. From this cohort, we compared patients with structurally normal hearts and normal EPI BIP voltage (EPI-, group 1) with patients with LVCM and low LV EPI BIP voltage regions present (EPI-, group 2). Confluent regions of ENDO UNI and EPI BIP low voltage (> 2 cm(2)) were measured. The normal signal amplitude was > 8.27 mV for LV ENDO UNI electrograms. Detailed LV ENDO-EPI maps in 5 EPI- patients were compared with 11 EPI+ patients. Confluent ENDO UNI low-voltage regions were seen in 9 of 11 (82%) of the EPI+ (group 2) patients compared with none of 5 EPI- (group 1) patients (P < 0.001). In all 9 patients with ENDO UNI low voltage, the ENDO UNI low-voltage regions were directly opposite to an area of EPI BIP low voltage (61% ENDO UNI-EPI BIP low-voltage area overlap). Conclusions-EPI arrhythmia substrate can be reliably identified in most patients with LVCM using ENDO UNI voltage mapping in the absence of ENDO BIP abnormalities. (Circ Arrhythm Electrophysiol. 2011;4:49-55.)

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available