4.8 Article

Left Ventricular Ejection Fraction Normalization in Cardiac Resynchronization Therapy and Risk of Ventricular Arrhythmias and Clinical Outcomes Results From the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT) Trial

Journal

CIRCULATION
Volume 130, Issue 25, Pages 2278-2286

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/CIRCULATIONAHA.114.011283

Keywords

arrhythmias, cardiac; cardiac resynchronization therapy; defibrillators, implantable; prognosis; ventricular dysfunction, left

Funding

  1. Boston Scientific

Ask authors/readers for more resources

Background-Appropriate guideline criteria for use of implantable cardioverter-defibrillators (ICDs) do not take into account potential recovery of left ventricular ejection fraction (LVEF) in patients treated with CRT-defibrillator. Methods and Results-Patients randomized to CRT-defibrillator from the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT) trial who survived and had paired echocardiograms at enrollment and at 12 months (n=752) were included. Patients were evaluated by LVEF recovery in 3 groups (LVEF <= 35% [reference], 36%-50%, and >50%) on outcomes of ventricular tachyarrhythmias (VTAs), VTA >= 200 bpm, ICD shock, heart failure or death, and inappropriate ICD therapy by multivariable Cox models. A total of 7.3% achieved LVEF normalization (>50%). The average follow-up was 2.2+/-0.8 years. The risk of VTA was reduced in patients with LVEF >50% (hazard ratio [HR], 0.24; 95% confidence interval [CI], 0.07-0.82; P=0.023) and LVEF of 36% to 50% (HR, 0.44; 95% CI, 0.28-0.68; P<0.001). Among patients with LVEF > 50%, only 1 patient had VTA >= 200 bpm (HR, 0.16; 95% CI, 0.02-1.51), none were shocked by the ICD, and 2 died of nonarrhythmic causes. The risk of HF or death was reduced with improvements in LVEF (LVEF > 50%: HR, 0.29; 95% CI, 0.09-0.97; P=0.045; and LVEF of 36%-50%: HR, 0.44; 95% CI, 0.28-0.69; P<0.001). For inappropriate ICD therapy, no additional risk reduction for LVEF>50% was seen compared with an LVEF of 36% to 50%. A total of 6 factors were associated with LVEF normalization, and patients with all factors present (n=42) did not experience VTAs (positive predictive value, 100%). Conclusions-Patients who achieve LVEF normalization (> 50%) have very low absolute and relative risk of VTAs and a favorable clinical course within 2.2 years of follow-up. Risk of inappropriate ICD therapy is still present, and these patients could be considered for downgrade from CRT-defibrillator to CRT-pacemaker at the time of battery depletion if no VTAs have occurred.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available