4.8 Article

Novel Single-Chain Antibody-Targeted Microbubbles for Molecular Ultrasound Imaging of Thrombosis Validation of a Unique Noninvasive Method for Rapid and Sensitive Detection of Thrombi and Monitoring of Success or Failure of Thrombolysis in Mice

Journal

CIRCULATION
Volume 125, Issue 25, Pages 3117-+

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/CIRCULATIONAHA.111.030312

Keywords

antibodies; platelets; molecular imaging; microbubbles; thrombosis; ultrasonography; thrombolysis

Funding

  1. National Heart Foundation of Australia
  2. Monash University
  3. Baker IDI Heart and Diabetes Institute
  4. Australian National Health and Medical Research Council
  5. Australian Research Council
  6. German Research Foundation

Ask authors/readers for more resources

Background-Molecular imaging is a fast emerging technology allowing noninvasive detection of vascular pathologies. However, imaging modalities offering high resolution currently do not allow real-time imaging. We hypothesized that contrast-enhanced ultrasound with microbubbles (MBs) selectively targeted to activated platelets would offer high-resolution, real-time molecular imaging of evolving and dissolving arterial thrombi. Methods and Results-Lipid-shell based gas-filled MBs were conjugated to either a single-chain antibody specific for activated glycoprotein IIb/IIIa via binding to a Ligand-Induced Binding Site (LIBS-MBs) or a nonspecific single-chain antibody (control MBs). Successful conjugation was assessed in flow cytometry and immunofluorescence double staining. LIBS-MBs but not control MBs strongly adhered to both immobilized activated platelets and microthrombi under flow. Thrombi induced in carotid arteries of C57Bl6 mice in vivo by ferric chloride injury were then assessed with ultrasound before and 20 minutes after MB injection through the use of gray-scale area intensity measurement. Gray-scale units converted to decibels demonstrated a significant increase after LIBS-MB but not after control MB injection (9.55 +/- 1.7 versus 1.46 +/- 1.3 dB; P < 0.01). Furthermore, after thrombolysis with urokinase, LIBS-MB ultrasound imaging allows monitoring of the reduction of thrombus size (P < 0.001). Conclusion-We demonstrate that glycoprotein IIb/IIIa-targeted MBs specifically bind to activated platelets in vitro and allow real-time molecular imaging of acute arterial thrombosis and monitoring of the success or failure of pharmacological thrombolysis in vivo. (Circulation. 2012;125:3117-3126.)

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available