Patient-Ventilator Asynchrony During Noninvasive Ventilation A Bench and Clinical Study

Journal

CHEST
Volume 142, Issue 2, Pages 367-376

Publisher

AMER COLL CHEST PHYSICIANS
DOI: 10.1378/chest.11-2279

Keywords

-

Funding

  1. Philips Respironics
  2. Annee Recherche
  3. Ministere de l'education nationale, de l'enseignement superieur et de la recherche (French Ministry for Education and Research)
  4. MAQUET GmbH Co KG
  5. Drager
  6. ResMed
  7. General Electric Company
  8. Covidien
  9. Fisher-Paykel

Ask authors/readers for more resources

Background: Different kinds of ventilators are available to perform noninvasive ventilation (NW) in ICUs. Which type allows the best patient-ventilator synchrony is unknown. The objective was to compare patient-ventilator synchrony during NIV between ICU, transport-both with and without the NIV algorithm engaged-and dedicated NIV ventilators. Methods: First, a bench model simulating spontaneous breathing efforts was used to assess the respective impact of inspiratory and expiratory leaks on cycling and triggering functions in 19 ventilators. Second, a clinical study evaluated the incidence of patient-ventilator asynchronies in 15 patients during three randomized, consecutive, 20-min periods of NIV using an ICU ventilator with and without its NIV algorithm engaged and a dedicated NIV ventilator. Patient-ventilator asynchrony was assessed using flow, airway pressure, and respiratory muscles surface electromyogram recordings. Results: On the bench, frequent auto-triggering and delayed cycling occurred in the presence of leaks using ICU and transport ventilators. NIV algorithms unevenly minimized these asynchronies, whereas no asynchrony was observed with the dedicated NIV ventilators in all except one. These results were reproduced during the clinical study: The asynchrony index was significantly lower with a dedicated NIV ventilator than with ICU ventilators without or with their NIV algorithm engaged (0.5% [0.4%-1.2%] vs 3.7% [1.4%-10.3%] and 2.0% [1.5%-6.6%], P < .01), especially because of less auto-triggering. Conclusions: Dedicated NIV ventilators allow better patient-ventilator synchrony than ICU and transport ventilators, even with their NIV algorithm. However, the NIV algorithm improves, at least slightly and with a wide variation among ventilators, triggering and/or cycling off synchronization. CHEST 2012; 142(2):367-376

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available