4.7 Article

Risk factors for ARDS in patients receiving mechanical ventilation for > 48 h

Journal

CHEST
Volume 133, Issue 4, Pages 853-861

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1378/chest.07-1121

Keywords

ARDS; lung injury; plateau pressure; tidal volume; transfusion; ventilator

Funding

  1. NHLBI NIH HHS [K24 HL093218] Funding Source: Medline
  2. NIA NIH HHS [K23 AG024837-04, K23 AG024837] Funding Source: Medline
  3. NIBIB NIH HHS [R01 EB 001659, R01 EB001659, R01 EB001659-05] Funding Source: Medline

Ask authors/readers for more resources

Background. Low tidal volume (VT) ventilation for ARDS is a well-accepted concept. However, controversy persists regarding the optimal ventilator settings for patients without ARDS receiving mechanical ventilation. This study tested the hypothesis that ventilator settings influence the development of new ARDS. Methods: Retrospective analysis of patients from the Multi Parameter Intelligent Monitoring of Intensive Care-II project database who received mechanical ventilation for 2: 48 h between 2001 and 2005. Results: A total of 2,583 patients required > 48 h of ventilation. Of 789 patients who did not have ARDS at hospital admission, ARDS developed in 152 patients (19%). Univariate analysis revealed high peak inspiratory pressure (odds ratio [OR], 1.53 per SD; 95% confidence interval [CI], 1.28 to 1.84), increasing positive end-expiratory pressure (OR, 1.35 per SD; 95% CI, 1.15 to 1.58), and VT (OR, 1.36 per SD; 95% CI, 1.12 to 1.64) to be significant risk factors. Major nonventilator risk factors for ARDS included sepsis, low pH, elevated lactate, low albumin, transfusion of packed RBCs, transfusion of plasma, high net fluid balance, and low respiratory compliance. Multivariable logistic regression showed that peak pressure (OR, 1.31 per SD; 95% CI, 1.08 to 1.59), high net fluid balance (OR, 1.35 per SD; 95% CI, 1.09 to 1.56), transfusion of plasma (OR, 1.26 per SD; 95% CI, 1.07 to 1.49), sepsis (OR, 1.57; 95% CI, 1.00 to 2.45), and VT (OR, 1.29 per SD; 95% CI, 1.02 to 1.52) were significantly associated with the development of ARDS. Conclusions: The associations between the development of ARDS and clinical interventions, including high airway pressures, high VT, positive fluid balance, and transfusion of blood products, suggests that ARDS may be a preventable complication in some cases.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available