4.0 Article

Real-time assessment of cigarette smoke particle deposition in vitro

Journal

CHEMISTRY CENTRAL JOURNAL
Volume 6, Issue -, Pages -

Publisher

BIOMED CENTRAL LTD
DOI: 10.1186/1752-153X-6-98

Keywords

QCM; Cigarette smoke; In vitro exposure chamber; Dosimetry

Ask authors/readers for more resources

Background: Recently there has been a rapid increase in approaches to assess the effects of cigarette smoke in vitro. Despite a range of gravimetric and chemical methods, there is a requirement to identify simpler and more reliable methods to quantify in vitro whole smoke dose, to support extrapolation and comparisons to human/in vivo dose. We have previously characterised an in vitro exposure system using a Borgwaldt RM20S smoking machine and a chamber exposing cellular cultures to whole smoke at the air-liquid interface. In this study we demonstrate the utility of a quartz crystal microbalance (QCM), using this exposure system, to assess real-time cigarette smoke particulate deposition during a 30 minute smoke exposure. Smoke was generated at various dilutions (1:5-1:400, smoke: air) using two cigarette products, 3R4F Kentucky reference and 1 mg commercially available cigarettes. The QCM, integrated into the chamber, assessed particulate deposition and data generated were compared to traditional chemical spectrofluorometric analysis. Results: The QCM chamber was able to detect mass differences between the different products within the nanogram range. 3R4F reference cigarette smoke deposition ranged from 25.75 +/- 2.30 mu g/cm(2) (1:5) to 0.22 +/- 0.03 mu g/cm(2) (1:400). 1 mg cigarette smoke deposition was less and ranged from 1.42 +/- 0.26 mu g/cm(2) (1:5), to 0.13 +/- 0.02 mu g/cm(2) (1:100). Spectrofluorometric analysis demonstrated statistically significant correlation of particulate deposition with the QCM (p < 0.05), and regression R-2 value were 97.4 %. The fitted equation for the linear model which describes the relationship is: QCM = -0.6796 + 0.9744 chemical spectrofluorescence. Conclusions: We suggest the QCM is a reliable, effective and simple tool that can be used to quantify smoke particulate deposition in real-time, in vitro and can be used to quantify other aerosols delivered to our chamber for assessment.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.0
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available