4.3 Article

SIMULATION OF SO2 ABSORPTION IN A VENTURI SCRUBBER

Journal

CHEMICAL ENGINEERING COMMUNICATIONS
Volume 197, Issue 7, Pages 934-952

Publisher

TAYLOR & FRANCIS INC
DOI: 10.1080/00986440903359137

Keywords

Mathematical model; Simulation; SO2 absorption; Venturi scrubber

Ask authors/readers for more resources

In this study, a three-dimensional mathematical model, based on a nonuniform droplet concentration distribution, has been developed to simulate gas absorption in a venturi scrubber. The mass transfer process was illustrated by assuming the liquid phase as a combination of droplets and film. The flow, just as the annular two-phase flow, includes a flow of liquid film layer on the walls and a flow of gas and liquid drops in the core. Peclet number was determined using experimental data reported by Viswanathan et al. (1984) for distribution of droplets across the cross section of the scrubber. The mathematical model for gas absorption was justified by comparing the theoretical predictions with the experimental data reported by Johnstone et al. (1954) and the Office of Air Programs, U.S. Environmental Protection Agency (Wen and Fan, 1975), for SO2 removal by alkaline solution and H2O.