4.7 Article

A full-Bayesian approach to parameter inference from tracer travel time moments and investigation of scale effects at the Cape Cod experimental site

Journal

WATER RESOURCES RESEARCH
Volume 36, Issue 1, Pages 159-171

Publisher

AMER GEOPHYSICAL UNION
DOI: 10.1029/1999WR900273

Keywords

-

Ask authors/readers for more resources

A method for inverting the travel time moments of solutes in heterogeneous aquifers is presented and is based on peak concentration arrival times as measured at various samplers in an aquifer. The approach combines a Lagrangian [Rubin and Dagan, 1992] solute transport framework with full-Bayesian hydrogeological parameter inference. In the full-Bayesian approach the noise values in the observed data are treated as hyperparameters, and their effects are removed by marginalization. The prior probability density functions (pdfs) for the model parameters (horizontal integral scale, velocity, and log K variance) and noise values are represented by prior pdfs developed from minimum relative entropy considerations. Analysis of the Cape Cod (Massachusetts) field experiment is presented. Inverse results for the hydraulic parameters indicate an expected value for the velocity, variance of log hydraulic conductivity, and horizontal integral scale of 0.42 m/d, 0.26, and 3.0 m, respectively. While these results are consistent with various direct-field determinations, the importance of the findings is in the reduction of confidence range about the various expected values. On selected control planes we compare observed travel time frequency histograms with the theoretical pdf, conditioned on the observed travel time moments. We observe a positive skew in the travel time pdf which tends to decrease as the travel time distance grows. We also test the hypothesis that there is no scale dependence of the integral scale lambda with the scale of the experiment at Cape God. We adopt two strategies. The first strategy is to use subsets of the full data set and then to see if the resulting parameter fits are different as we use different data from control planes at expanding distances from the source. The second approach is from the viewpoint of entropy concentration. No increase in integral scale with distance is inferred from either approach over the range of the Cape Cod tracer experiment.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available