4.6 Article

Interval partial least-squares regression (iPLS): A comparative chemometric study with an example from near-infrared spectroscopy

Journal

APPLIED SPECTROSCOPY
Volume 54, Issue 3, Pages 413-419

Publisher

SOC APPLIED SPECTROSCOPY
DOI: 10.1366/0003702001949500

Keywords

interval PLS; variable selection; NIR, principal variables; forward stepwise selection; recursively weighted regression; beer; extract

Ask authors/readers for more resources

A new graphically oriented local modeling procedure called interval partial least-squares (iPLS) is presented for use on spectral data. The iPLS method is compared to full-spectrum partial least-squares and the variable selection methods principal variables (PV), forward stepwise selection (FSS), and recursively weighted regression (RWR). The methods are tested on a near-infrared (NIR) spectral data set recorded on 60 beer samples correlated to original extract concentration. The error of the full-spectrum correlation model between NIR and original extract concentration was reduced by a factor of 4 with the use of iPLS (r = 0.998, and root mean square error of prediction equal to 0.17% plate), and the graphic output contributed to the interpretation of the chemical system under observation. The other methods tested gave a comparable reduction in the prediction error but suffered from the interpretation advantage of the graphic interface. The intervals chosen by iPLS cover both the variables found by FSS and all possible combinations as well as the variables found by PV and RWR, and iPLS is still able to utilize the first-order advantage.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available