4.7 Article

Microfluidic devices fabricated in poly( methyl methacrylate) using hot-embossing with integrated sampling capillary and fiber optics for fluorescence detection

Journal

LAB ON A CHIP
Volume 2, Issue 2, Pages 88-95

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/b200370h

Keywords

-

Funding

  1. NATIONAL CANCER INSTITUTE [R24CA084625] Funding Source: NIH RePORTER
  2. NATIONAL HUMAN GENOME RESEARCH INSTITUTE [R01HG001499] Funding Source: NIH RePORTER
  3. NCI NIH HHS [R24-CA84625] Funding Source: Medline
  4. NHGRI NIH HHS [R01-HG01499] Funding Source: Medline

Ask authors/readers for more resources

High-aspect-ratio microstructures have been prepared using hot-embossing techniques in poly( methyl methacrylate) (PMMA) from Ni-based molding dies prepared using LIGA (Lithographie, Galvanoformung, Abformung). Due to the small amount of mask undercutting associated with X-ray lithography and the high energy X-ray beam used during photoresist patterning, deep structures with sharp and smooth sidewalls have been prepared. The Ni-electroforms produced devices with minimal replication errors using hot-embossing at a turn around time of 5 min per device. In addition, several different polymers (with different glass transition temperatures) could be effectively molded with these Ni-electroforms and many devices ( > 300) molded with the same master without any noticeable degradation. The PMMA devices consisted of deep and narrow channels for insertion of a capillary for the automated electrokinetic loading of sample into the microfluidic device and also, a pair of optical fibers for shuttling laser light to the detection zone and collecting the resulting emission for fluorescence analysis. Electrophoretic separations of double-stranded DNA ladders Phi X174 digested with Hae III) were performed with fluorescence detection accomplished using near-IR excitation. It was found that the narrow width of the channels did not contribute significantly to electrophoretic zone broadening and the plate numbers generated in the extended length separation channel allowed sorting of the 271/ 281 base pair fragments associated with this sizing ladder when electrophoresed in methylcellulose entangled polymer solutions. The dual fiber detector produced sub-attomole detection limits with the entire detector, including laser source, electronics and photon transducer, situated in a single box measuring 3 X 10 X 14.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available