4.4 Article

Discharge studies and prevention in the gas electron multiplier (GEM)

Publisher

ELSEVIER
DOI: 10.1016/S0168-9002(01)00931-7

Keywords

gas electron multiplier; GEM; gas discharges; streamer; high rate radiation detector

Ask authors/readers for more resources

The gas electron multiplier (GEM) used as single proportional counter or in a cascade of two or more elements, permits to attain high gains and to perform detection and localization of ionizing tracks at very high radiation rates. As in other micro-pattern detectors, however, the occasional occurrence of heavily ionizing trails may trigger a local breakdown, with possible harmful consequences on the device itself and on the readout electronics. This paper describes a systematic investigation of the discharge mechanisms in single and multiple GEM structures, and suggests various strategies to reduce both the energy and the probability of the discharges. (C) 2002 Elsevier Science B.V. All rights reserved.