4.6 Article

Liquid-phase microextraction of protein-bound drugs under non-equilibrium conditions

Journal

ANALYST
Volume 127, Issue 5, Pages 608-613

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/b110105f

Keywords

-

Ask authors/readers for more resources

Recently, we introduced an inexpensive and disposable hollow fiber-based device for liquid-phase microextraction (LPME) where ionic analytes typically were extracted and preconcentrated from 1-4 mL aqueous samples (such as plasma and urine) through an organic solvent immobilized in the pores of a polypropylene hollow fiber and into a 10-25 muL volume of acceptor phase present inside the lumen of the hollow fiber. Subsequently, the acceptor phase was directly subjected to the final analysis by a chromatographic or electrophoretic method. In the present work, attention was focused on LPME of the basic drugs amphetamine, pethidine, promethazine, methadone and haloperidol characterized by substantial differences in the degree of protein binding. Drug-protein interactions in plasma resulted in reduced recoveries and substantially increased extraction times compared with extraction of the drugs from a pure water matrix. However, by addition of 5-50% methanol to the plasma samples, recoveries were comparable with LPME from water samples and ranged between 75 and 100%. The addition of methanol was found not to speed up the LPME process and extractions from plasma were performed in 45 min to reach equilibrium. Because approximately 55-70% of the final analyte concentrations were achieved within the initial 10 min of the LPME process, validation was accomplished after 10 and 45 min of LPME. In general, the results with 10 and 45 min were almost comparable, with precision data in the range 1.2-11.1% (RSD) and with linearity in the concentration range 20-1000 ng mL(-1) (r = 0.999). In conclusion, excellent LPME results may be achieved in a short time under non-equilibrium conditions with a minor loss of sensitivity. In cases of drug-protein interactions, methanol may be added to ensure a high extraction recovery.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available