RF safety of wires in interventional MRI: Using a safety index

Journal

MAGNETIC RESONANCE IN MEDICINE
Volume 47, Issue 1, Pages 187-193

Publisher

JOHN WILEY & SONS INC
DOI: 10.1002/mrm.10037

Keywords

MRI safety; RF heating; interventional MRI; moment method; metallic implants

Funding

  1. NATIONAL HEART, LUNG, AND BLOOD INSTITUTE [R01HL061672] Funding Source: NIH RePORTER
  2. NHLBI NIH HHS [R01 HL61672] Funding Source: Medline

Ask authors/readers for more resources

With the rapid growth of interventional MRI, radiofrequency (RF) heating at the tips of guidewires, catheters, and other wire-shaped devices has become an important safety issue. Previous studies have identified some of the variables that affect the relative magnitude of this heating but none could predict the absolute amount of heating to formulate safety margins. This study presents the first theoretical model of wire tip heating that can accurately predict its absolute value, assuming a straight wire, a homogeneous RF coil, and a wire that does not extend out of the tissue. The local specific absorption rate (SAR) amplification from induced currents on insulated and bare wires was calculated using the method of moments. This SAR gain was combined with a semianalytic solution to the bioheat transfer equation to generate a safety index. The safety index (degreesC/(W/kg)) is a measure of the in vivo temperature change that can occur with the wire in place, normalized to the SAR of the pulse sequence. This index can be used to set limits on the spatial peak SAR of pulse sequences that are used with the interventional wire. For the case of a straight resonant wire in a tissue with very low perfusion, only about 100 mW/kg/degreesC spatial peak SAR may be used at 1.5 T. But for less than or equal to 10-cm wires with an insulation thickness greater than or equal to 30% of the wire radius that are placed in well-perfused tissues, normal operating conditions of 4 W/kg spatial peak SAR are possible at 1.5 T. Further model development to include the influence of inhomogeneous RF, curved wires, and wires that extend out of the sample are required to generate safety indices that are applicable to common clinical situations. We propose a simple way to ensure safety when using an interventional wire: set a limit on the SAR of allowable pulse sequences that is a factor of a safety index below the tolerable temperature increase. Magn Reson Med 47:187-193, 2002. (C) 2002 Wiley-Liss, Inc.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available