Journal
ELECTROPHORESIS
Volume 24, Issue 21, Pages 3633-3639Publisher
WILEY-V C H VERLAG GMBH
DOI: 10.1002/elps.200305621
Keywords
capillary microreactor; immobilized enzyme; matrix assisted laser desorption/ionization-time of flight-mass spectrometry; metal-ion chelated adsorption; miniaturization; peptide mapping analysis
Ask authors/readers for more resources
Peptide mass mapping analysis, utilizing a regenerable enzyme microreactor with metal-ion chelated adsorption of enzyme, combined with matrix assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS) was developed. Different procedures from the conventional approaches were adopted to immobilize the chelator onto the silica supports, that is, the metal chelating agent of iminodiacetic acid (IDA) was reacted with glycidoxypropyltrimethoxysilane (GLYMO) before its immobilization onto the inner wall of the fused-silica capillary pretreated with NH4HF2. The metal ion of copper and subsequently enzyme was specifically adsorbed onto the surface to form the immobilized enzyme capillary microreactor, which was combined with MALDI-TOF-MS to apply for the mass mapping analysis of nL amounts of protein samples. The results revealed that the peptide mapping could routinely be generated from 0.5 pmol protein sample in 15 min at 50degreesC, even 20 fmol cytochrome c could be well digested and detected.