4.7 Article

Fatigue failure of ferroelectric ceramics subjected to cyclic inclined electric loading

Journal

SCRIPTA MATERIALIA
Volume 49, Issue 9, Pages 849-854

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/S1359-6462(03)00445-7

Keywords

ferroelectric ceramic; fatigue; crack deflection

Ask authors/readers for more resources

Experimental tests were carried out on a series of ferroelectric specimens (PZT-5) with cracks of different inclined angles, subjected to alternate electric fields. The cracks were found to deviate from their original plane for all inclined angles. The dominant factor of electric fatigue was found to be the ratio of the applied electric field to the coercive field. (C) 2003 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.