4.6 Article Proceedings Paper

Statistical validation based on parametric receiver operating characteristic analysis of continuous classification data

Journal

ACADEMIC RADIOLOGY
Volume 10, Issue 12, Pages 1359-1368

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/S1076-6332(03)00538-5

Keywords

brain segmentation; magnetic resonance; prostate specific antigen (PSA); genitourinary system; computed tomography; receiver operating characteristic (ROC) analysis

Funding

  1. AGENCY FOR HEALTHCARE RESEARCH AND QUALITY [R03HS013234] Funding Source: NIH RePORTER
  2. NATIONAL CANCER INSTITUTE [P01CA067165, R21CA089449, R01CA086879, P01CA041167] Funding Source: NIH RePORTER
  3. NATIONAL CENTER FOR RESEARCH RESOURCES [R01RR011747, P41RR013218] Funding Source: NIH RePORTER
  4. NATIONAL INSTITUTE ON AGING [R01AG019513] Funding Source: NIH RePORTER
  5. NATIONAL LIBRARY OF MEDICINE [R01LM007861] Funding Source: NIH RePORTER
  6. AHRQ HHS [R03 HS013234, R03HS13234-01] Funding Source: Medline
  7. NCI NIH HHS [R01 CA086879, R01CA86879, P01CA67165, P01 CA067165, P01CA41167, R21CA89449-01] Funding Source: Medline
  8. NCRR NIH HHS [P41RR13218, R01RR11747, P41 RR013218] Funding Source: Medline
  9. NIA NIH HHS [R01 AG019513, R01AG19513] Funding Source: Medline
  10. NLM NIH HHS [R01 LM007861, R01LM7861] Funding Source: Medline
  11. PHS HHS [U0145356] Funding Source: Medline

Ask authors/readers for more resources

Rationale and Objectives. The accuracy of diagnostic test and imaging segmentation is important in clinical practice because it has a direct impact on therapeutic planning. Statistical validations of classification accuracy was conducted based on parametric receiver operating characteristic analysis, illustrated on three radiologic examples. Materials and Methods. Two parametric models were developed for diagnostic or imaging data. Example 1: A semi-automated fractional segmentation algorithm was applied to magnetic resonance imaging of nine cases of brain tumors. The tumor and background pixel data were assumed to have bi-beta distributions. Fractional segmentation was validated against an estimated composite pixel-wise gold standard based on multi-reader manual segmentations. Example 2: The predictive value of 100 cases of spiral computed tomography of ureteral stone sizes, distributed as bi-normal after a non-linear transformation, under two treatment options received. Example 3: One hundred eighty cases had prostate-specific antigen levels measured in a prospective clinical trial. Radical prostatectomy was performed in all to provide a binary gold standard of local and advanced cancer stages. Prostate-specific antigen level was transformed and modeled by bi-normal distributions. In all examples, areas under the receiver operating characteristic curves were computed. Results. The areas under the receiver operating characteristic curves were: Example 1: Fractional segmentation of magnetic resonance imaging of brain tumors: meningiomas (0.924-0.984); astrocytomas (0.786-0.986); and other low-grade gliomas (0.896-0.983). Example 3: Ureteral stone size for treatment planning (0.813). Example 2: Prostate-specific antigen for staging prostate cancer (0.768). Conclusion. All clinical examples yielded fair to excellent accuracy. The validation metric area under the receiver operating characteristic curves may be generalized to evaluating the performances of several continuous classifiers related to imaging.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available