4.5 Article Proceedings Paper

Purification and partial characterization of feline alpha(1)-proteinase inhibitor (f alpha(1)-PI) and the development and validation of a radioimmunoassay for the measurement of f alpha(1)-PI in serum

Journal

BIOCHIMIE
Volume 86, Issue 1, Pages 67-75

Publisher

EDITIONS SCIENTIFIQUES MEDICALES ELSEVIER
DOI: 10.1016/j.biochi.2003.10.005

Keywords

feline; alpha(1)-proteinase inhibitor; purification; trypsin inhibitory activity; isoelectric focusing; N-terminal amino acid sequence; anti-feline alpha(1)-PI antibodies; radioimmunoassay

Ask authors/readers for more resources

Alpha I-proteinase inhibitor (alpha(1)-PI) of the domestic cat (Felis catus) was purified from serum and a radioimmunoassay (RIA) for the measurement of feline alpha(1)-Pl concentration in serum was developed and validated. Feline alpha(1)-PI (falpha(1)-PI) was isolated using ammonium sulfate precipitation, anion-exchange, size-exclusion, ceramic hydroxyapatite, and hydrophobic interaction chromatography. The molecular weight of falpha(1)-PI was estimated at 57,000 and the relative molecular mass (M-r) was determined to be approximately 54.5 kDa. Isoelectric focusing revealed four bands with isoelectric points (pI) between 4.3 and 4.5. The N-terminal amino acid sequence of the first 19 residues was G I Gly-Leu-Gln-Gly-Ala-Ala-Val-Gln-Glu-Thr-Val-Ala-Ser-Gln-His-Asp-Gln-Glu.. Anti serum against feline alpha(1)-PI was raised in rabbits. Tracer was produced by iodination (I-125) of feline alpha(1)-PI using the chloramine T method. A radioimmunoassay was established and validated by determination of sensitivity, dilutional parallelism, spiking recovery, intra-assay variability, and inter-assay variability. A control range for serum feline alpha(1)-PI concentration was established from 50 healthy cats using the central 95th percentile. The sensitivity of the assay was 0.042 mg/ml. Observed to expected ratios for serial dilutions ranged from 105% to 141.18% for four different serum samples at dilutions of 1 in 35,000, 1 in 70,000, 1 in 140,000 and 1 in 280,000. Observed to expected ratios for spiking recovery ranged from 88.14% to 152.17% for four different serum samples and five different spiking concentrations. Coefficients of variation for four different serum samples were 4.57%, 6.45%, 8.52%, and 4.27% for intra-assay variability and 6.88%, 9.57%, 7.44%, and 9.94% for inter-assay variability. The reference range was established as 0.25-0.6 mg/ml. In summary, feline alpha(1)-PI was successfully Purified front serum using a rapid and efficient method. The radioimmunoassay described here is sensitive, linear, accurate, precise, and reproducible and will facilitate further Studies of the physiological or potential pathological role of alpha(1)-PI in cats. (C) 2003 editions scientifiques et medicales Elsevier SAS. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available