3.9 Article

The orientation-averaged aspiration efficiency of IOM-like personal aerosol samplers mounted on bluff bodies

Journal

ANNALS OF OCCUPATIONAL HYGIENE
Volume 48, Issue 1, Pages 3-11

Publisher

OXFORD UNIV PRESS
DOI: 10.1093/annhyg/meg088

Keywords

aerosol sampling; aspiration efficiency; bluff body; inhalable sampling; IOM sampler; mannequin; orientation averaging; particle size-selective criteria; Stokes' number; wind tunnel

Funding

  1. NIOSH CDC HHS [5-R01-OH0387-09] Funding Source: Medline

Ask authors/readers for more resources

This paper describes two sets of experiments that were intended to characterize the orientation-averaged aspiration efficiencies of IOM samplers mounted on rotating bluff bodies. IOM samplers were mounted on simplified, three-dimensional rectangular bluff bodies that were rotated horizontally at a constant rate. Orientation-averaged aspiration efficiencies (A(360)) Were measured as a function of Stokes' number (St), velocity ratio (R) and dimension ratio (r). Aspiration efficiency (A) is the efficiency with which particles are transported from the ambient air into the body of a sampler, and A(360) is A averaged over all orientations to the wind. St is a dimensionless variable that represents particle inertia, R is the ratio of the air velocity in the freestream and that at the plane of the sampler's entry orifice, and r is the ratio of the sampler's orifice diameter and the bluff body's width. The first set of experiments were instrumental in establishing a hierarchy of effects on orientation-averaged A. It was clear that compared to r, St had a much larger influence on A. It was also clear, however, that the effects of St were overpowered by the effects of R in many cases. As concluded in previous studies, R and St were considered the most important factors in determining A, even for A(360). The second set of experiments investigated A(360) of IOM samplers for a much wider range of r than examined in previous research. Two important observations were made from the experimental results. One was that the A(360) of IOM samplers, as a function of St, did not change for an r-range of 0.066-0.4. This meant that an IOM sampler mounted on a near life-size mannequin would measure the same aerosol concentration as one not mounted on anything. The second observation was that the aspiration efficiency curve of the IOM sampler was close to the inhalability curve. This gave further evidence that the bluff body did not play a major role in influencing A(360), as the IOM samplers, in these experiments, were either mounted on miniature bluff bodies or on nothing at all. These observations all suggest that it is quite possible to design and test personal samplers with desired sampling characteristics using protocols that do not require full-size mannequins, which greatly simplifies the development of new samplers.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.9
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available