A prospective study of the impact of automated dipstick urinalysis on the diagnosis of preeclampsia

Journal

HYPERTENSION IN PREGNANCY
Volume 23, Issue 2, Pages 135-142

Publisher

TAYLOR & FRANCIS INC
DOI: 10.1081/PRG-120028289

Keywords

preeclampsia; automated dipstick urinalysis; proteinuria; protein/creatinine ratio

Ask authors/readers for more resources

Objective: To determine prospectively in hypertensive pregnant women 1) the accuracy of dipstick testing for proteinuria using automated urinalysis, 2) factors that might affect such accuracy, and 3) the potential impact of automated dipstick testing on the accuracy of diagnosis of preeclampsia according to acceptance of proteinuria at either 1+ or 2+ level. Design: Prospective study. Setting: Antenatal day assessment unit and antenatal ward of St George Hospital, a teaching hospital in Sydney, Australia. Population: 170 hypertensive pregnant women attending as outpatients or inpatients. Methods: 503 midstream urine samples were collected prospectively on separate occasions from 170 women. Full urinalysis was recorded using the Bayer Clinitek 50 automated urinalysis device and Multistix 10SG urinalysis strips (Bayer Diagnostics, Victoria, Australia). Each MSU was analysed for spot protein/creatinine ratio and also for culture and sensitivity if symptoms of a urinary tract infection were present or dipstick included positive nitrites. Urinalysis protein results were compared with spot urinary protein/creatinine ratio (previously shown to correlate with 24-hr urine protein excretion) to determine the accuracy of urinalysis. True proteinuria was defined as a ratio greater than or equal to 30 mg protein/mmol creatinine. Results: False positive dipstick tests ranged from 7% at 3+ level to 71% at I + proteinuria level while false negative rates were 7% for nil and 14% for trace proteinuria, 9% overall. Accepting the dipstick proteinuria result at face value led to an incorrect diagnosis of preeclampsia or gestational hypertension in 85 (50%) women. Dipstick proteinuria was significantly more likely to be correct (true positive/true negative) if diastolic blood pressure was elevated > 90 mmHg (p = 0.032) and in the absence of ketonuria (p = 0.001). Accepting a diagnosis of preeclampsia on the basis of de novo hypertension and dipstick testing alone was accurate less often (70%) when >1+ was used as a discriminant value than at the 82% of presentations when >2+ was used (p = 0.001). Conclusion: Accepting nil or trace proteinuria as a true negative dipstick results fails to identify approximately I in I I hypertensive pregnant women with true proteinuria, a false negative rate that may be acceptable provided these women are subject to ongoing vigilant clinical review. Even with automated urinalysis the false positive rate for dipstick levels >1+ is very high, particularly in the presence of ketonuria and relying on this alone to diagnose preeclampsia leads to significant errors in diagnosis. Accepting >2+ dipstick proteinuria improves overall diagnostic accuracy for preeclampsia at the expense of a higher false negative rate. This study emphasizes the need to confirm dipstick proteinuria with a further test such as a spot urine protein/creatinine ratio in all hypertensive pregnant women, particularly in research studies.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available