4.1 Article

Increased P-wave dispersion predicts recurrent atrial fibrillation after cardioversion

Journal

JOURNAL OF ELECTROCARDIOLOGY
Volume 38, Issue 1, Pages 43-46

Publisher

CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS
DOI: 10.1016/j.jelectrocard.2004.09.008

Keywords

atrial fibrillation; P-wave dispersion; cardioversion

Ask authors/readers for more resources

Atrial fibrillation (AF) will recur in a number of patients treated with cardioversion. Being able to identify reliable risk factors would be useful for making management decisions. P-wave dispersion (PWD) is an electrocardiographic measurement, which reflects a disparity in atrial conduction. P-wave dispersion has been shown to be increased in patients with paroxysmal AF. This pilot study aims to determine the role of PWD in predicting AF recurrence in patients who underwent elective cardioversion. Forty-five patients who were successfully cardioverted for persistent AF were included for study. Eighteen patients had a PWD greater than 80 ms; of these 13 had AF recurrence. Of the 25 patients with PWD less than 80 milliseconds, 12 had recurrent AF. P-wave dispersion values greater than 80 milliseconds were found more frequently in patients with AF recurrence (P = .05), supporting the use of this parameter in predicting return of AF. Larger studies are needed for further evaluation. Published by Elsevier Inc.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available