4.8 Article

Real time monitoring of the drug release of rhodamine B on graphene oxide

Journal

CARBON
Volume 49, Issue 4, Pages 1126-1132

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.carbon.2010.11.026

Keywords

-

Funding

  1. Sundsvall Community

Ask authors/readers for more resources

A real time method for monitoring the drug load and release on graphene oxide (GO) in a cuvette is reported using rhodamine B (RB) as a model for a drug. The mechanisms of the release of RB at different pH were investigated, by monitoring the time dependency of the accumulative drug release. In vitro real time experimental results indicated that RB could be loaded on GO with a capacity of 0.5 mg/mg. The drug release of RB was pH sensitive as observed at pH 7.4 and pH 4.5 PBS solutions. The higher pH values lead to weaker hydrophobic force and hydrogen bonds, and thus higher release rate. The ionic strength also influenced the release of RB, as shown from the different release rates between PBS solutions and double distilled water. These results indicated a case II transport process at pH 7.4 and an anomalous diffusion process at pH 4.5 and in water. The method described here allows real time detection of the drug release rate, in contrast to common dialysis analysis. This method also points to other real time detections in biomedical investigations. (C) 2010 Elsevier Ltd. All rights reserved.