4.4 Article

Implant stability during initiation and resolution of experimental periimplantitis: An experimental study in the dog

Journal

CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH
Volume 7, Issue 3, Pages 136-140

Publisher

BLACKWELL PUBLISHING
DOI: 10.1111/j.1708-8208.2005.tb00057.x

Keywords

bone loss; radiography; reosseointegration; resonance frequency analysis

Ask authors/readers for more resources

Background: Histologic studies have demonstrated the possibility to reestablish direct bone-implant contacts after ligature-induced periimplantitis. The influence of the reosseointegration on the stability of implants is not known. Purpose: The aim of the present investigation was to study bone tissue and associated implant stability alterations that occurred during induction and resolution of periimplantitis using resonance frequency analysis (RFA), radiography, and histology. Materials and Methods: Three implants with smooth (turned) or roughened (SLA(R)) surfaces were placed in each side of the edentulous mandible of four dogs. Experimental periimplantitis was induced. for 3 months. Five weeks later, the animals were treated with antibiotics and surgical therapy and were followed for another 6 months. Periapical radiographs and RFA were used to evaluate marginal bone levels and implant stability throughout the study period. After termination, the tissue-implant interface was evaluated by light microscopy in ground sections. Results: There was a linear relationship between radiographic and RFA findings because continuous loss of marginal bone and a decrease in implant stability were observed for both implant surfaces during the periimplantitis period. Antibiotic treatment and surgical therapy resulted in some reosseointegration, which was more marked for the SLA surface. The resonance frequency values corresponded well to the histometric measurements because reosseointegration resulted in an increase in implant stability. Conclusions: The findings from the present study indicate a linear relationship between marginal bone level and resonance frequency value. It is suggested that the RFA technique is sensitive and may be used to detect even a minor change in the level of bone-implant contact.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available