Minimum audible angle, just noticeable interaural differences and speech intelligibility with bilateral cochlear implants using clinical speech processors

Journal

AUDIOLOGY AND NEURO-OTOLOGY
Volume 10, Issue 6, Pages 342-352

Publisher

KARGER
DOI: 10.1159/000087351

Keywords

cochlear implantation; bilateral; speech intelligibility; sound localization; minimum audible angle; binaural hearing; interaural intensity discrimination; interaural time discrimination

Ask authors/readers for more resources

Sound localization and speech intelligibility were assessed in 5 patients implanted bilaterally with Medel C40+ or Medel C40 cochlear implant (CI) systems. The minimum audible angle (MAA) around the head in the horizontal plane was assessed in patients with bilateral CI using white noise bursts of 1000 ms duration presented from a loudspeaker mounted on a rotating boom and compared with the MAA of age-matched normal hearing controls. Spatial discrimination was found to be good in front and in the back of the head with near-normal MAA values (patients: 3-8 degrees, controls: 1-4 degrees). In contrast, poor performance on the sides was found (patients: 30 to over 45, controls 7-10 degrees). Bilateral CI significantly improved spatial discrimination in front for all patients, when compared with the use of either CI alone. Just noticeable differences (JNDs) in interaural intensity and time were assessed using white noise bursts (1000 ms duration; 50 ms linear ramp). In addition, interaural time JNDs were assessed using click trains (800 ms duration, 40 mu s clicks, 50 Hz) and noise bursts in which either only the envelope or only the fine structure was shifted in time. In comparison with normal hearing controls, patients with bilateral CI showed near-normal interaural intensity JNDs but substantially poorer interaural time JNDs depending on the type of stimulus. In contrast to envelope onset/offset cues, interaural fine structure time differences were not perceived by the patients using CI systems employing the continuous interleaved sampling strategy without synchronization between their pulse stimulation times. Speech intelligibility in quiet and CCITT noise from the side ( 8 90) was assessed using the German HSM sentence test and was significantly better when using bilateral CI in comparison with either unilateral CI, mainly due to a head shadow effect. These favorable results are in agreement with the patients' subjective experiences assessed with a questionnaire and support the use of bilateral CI. Copyright (C) 2005 S. Karger AG, Basel.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available