4.5 Article

Clinical and radiographic effects of enamel matrix derivative in the treatment of intrabony periodontal defects: A 12-month longitudinal placebo-controlled clinical trial in adult periodontitis patients

Journal

JOURNAL OF PERIODONTOLOGY
Volume 76, Issue 1, Pages 129-133

Publisher

WILEY
DOI: 10.1902/jop.2005.76.1.129

Keywords

bone loss/etiology; clinical trials, controlled; clinical trials, randomized; enamel matrix derivative; periodontal diseases/complications

Ask authors/readers for more resources

Background: This randomized, double-masked, placebo-controlled clinical trial evaluated the effect of enamel matrix derivative (EMD) on clinical and radiographic parameters of periodontal intrabony defects. Methods: A split-mouth design was used in 16 chronic periodontitis patients who had similar defects (>= 6 mm of probing depth). Both groups underwent scaling and root planing and were acid-etched with EDTA. The test sites received the EMD solution and the controls a placebo. Clinical examinations of all 16 patients and radiographs of 14 patients were available at baseline and 6 and 12 months after surgery. Clinical outcomes included probing depth (PD) and clinical attachment level (CAL); radiographic analysis was performed using computerized linear measurements. Intergroup comparisons were performed by paired samples t test, and over time comparisons were made by general linear model (alpha = 0.05). Results: A statistically significant improvement over time for PD and CAL and a decrease of the vertical component of the defect was detected in both groups. Comparisons between groups revealed at baseline a mean +/- SD value of CAL of 12.93 +/- 2.00 and 13.47 +/- 2.93 for test and control groups, respectively. These values decreased to 10.92 +/- 1.92 and 11.31 +/- 1.86 after 12 months for test and control. No statistically significant differences could be observed between groups. PD displayed similar results from 7.57 +/- 1.02 and 7.38 +/- 1.16 for test and control groups at baseline to 3.40 +/- 1.82 and 2.99 +/- 1.07 after 12 months. If the data are divided into smokers and non-smokers, no differences are observed. Conclusion: Use of EMD did not result in more improvement in clinical and radiographic parameters compared to the placebo.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available