4.4 Article

Aortic compliance following EVAR and the influence of different endografts: Determination using dynamic MRA

Journal

JOURNAL OF ENDOVASCULAR THERAPY
Volume 13, Issue 3, Pages 406-414

Publisher

SAGE PUBLICATIONS INC
DOI: 10.1583/06-1848.1

Keywords

abdominal aortic aneurysm; endovascular repair; stent-graft; aortic compliance; elastic modulus; stiffness; sac diameter; magnetic resonance imaging; dynamic imaging; dynamic MRA

Ask authors/readers for more resources

Purpose: To utilize dynamic magnetic resonance angiography (MRA) to characterize aortic stiffness (beta) and elastic modulus (Ep) as indexes of wall compliance during the cardiac cycle and determine any influence of different endograft designs or the presence of endoleaks on these indexes. Methods: Eleven consecutive patients (11 men; median age 74 years, range 63-78) with abdominal aortic aneurysm (AAA) selected for endovascular repair were scanned pre- and postoperatively. Aortic area and diameter changes during the cardiac cycle were determined using dynamic MRA at 4 levels: 3 cm above the renal arteries, between the renal arteries, 1 cm below the renal arteries, and at the level of maximum aneurysm sac diameter. Ep and beta were calculated. Data are presented as median (range); p<0.05 was considered significant. Results: Preoperatively, Ep and beta were significantly higher at the level of the aneurysm sac compared to all other levels (p<0.05). Following EVAR, stiffness increased at this level (p<0.05). After implantation, patients with an Excluder endograft demonstrated Ep and beta measurements at the aneurysm neck that were 94% and 60% higher, respectively, compared to those with a Talent (p<0.05) endograft. The presence of an endoleak had no effect on Ep or beta. Conclusion: This study introduces the feasibility of dynamic MRA imaging-based calculations of aortic elastic modulus and stiffness. AAA patients demonstrate increased Ep and beta at the level of the aneurysm sac. EVAR results in increased aneurysm sac Ep and beta. Stent-graft design seems to alter Ep and beta within the aneurysm neck, which may have consequences for endograft durability. The presence of an endoleak does not seem to have an effect on Ep or beta.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available