Ask authors/readers for more resources

Despite spontaneous sprouting of peripheral axons after transection injury, peripheral regeneration is incomplete and limited to short gaps, even with the use of autograft tissue, which is considered to be the gold standard. In an attempt to obviate some of the problems associated with autografts, including limited donor tissue and donor site morbidity, we aimed to synthesize a synthetic nerve guidance channel that would perform as well as the nerve autograft. Given that the patency of the nerve guidance channel is critical for repair, we investigated a series of nerve guidance channel designs where patency and the resulting regenerative capacity were compared in a transected rat sciatic nerve injury model. Three tube designs were compared to autograft tissue: plain, corrugated and coil-reinforced tubes of poly(2-hydroxyethyl methacrylate-co-methyl methacrylate). Of the three designs, the coil-reinforced tubes demonstrated superior performance in terms of patency. By electrophysiology and histomorphometry, the coil-reinforced tubes demonstrated outcomes that were comparable to autografts after both 8 and 16 weeks of implantation. The nerve action potential (NAP) velocity and muscle action potential (MAP) velocity for the coil-reinforced PHEMA-MMA tube was 54.6 +/- 10.1 and 10.9 +/- 1.3 m/s, respectively at 16 weeks, which was statistically equivalent to those of the autograft at 37.5 +/- 7.9 and 11.3 +/- 2.0 m/s. The axon density in the coil-rein forced tube was 2.16 +/- 0.61 x 10(4) axons/mm(2), which was statistically similar to that of the autograft of 2.41 +/- 0.62 x 10(4) axons/mm(2) at 16 weeks. These coil-reinforced tubes demonstrated equivalence to autografts for nerve regeneration, demonstrating the importance of channel design to regenerative capacity and more specifically the impact of patency to regeneration. (c) 2005 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available