4.4 Article

Adsorptive cathodic stripping voltammetry determination of ultra trace of lead in different real samples

Journal

ANALYTICAL LETTERS
Volume 40, Issue 14, Pages 2693-2707

Publisher

TAYLOR & FRANCIS INC
DOI: 10.1080/00032710701588069

Keywords

carbidopa; lead; adsorptive cathodic stripping voltammetry

Ask authors/readers for more resources

In the present work, an adsorptive cathodic stripping voltammetric method using a hanging mercury drop electrode (HMDE) was described in order to determine the ultra trace of lead ions with carbidopa in different real samples. The method is based on accumulation of lead metal ion on mercury electrode using carbidopa as a suitable complexing agent. The potential was scanned to the negative direction and the differential pulse stripping voltammograms were recorded. The instrumental and chemical parameters were optimized. The optimized conditions were obtained in pH of 8.4, carbidopa amount of 1.0 x 10(-6) M, accumulation potential of 0.0 V, accumulation time of 100 s, scan rate of 100 mV/s and pulse height of 50 mV. The relationship between the peak current versus concentration was linear over the range of 2.4 x 10(-10) -4.8 x 10(-7) M. The limits of detection were 5.8 x 10(-11) M and the relative standard deviation at 4.8 x 10(-10), 2.1 x 10(-8), and 2.4 x 10(-7) M of lead ion were obtained 3.2, 2.9, and 2.7%, respectively (n = 7).

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available