4.6 Article

Significance of the HO2+CO reaction during the combustion of CO+H-2 mixtures at high pressures

Journal

PROCEEDINGS OF THE COMBUSTION INSTITUTE
Volume 31, Issue -, Pages 419-427

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.proci.2006.07.068

Keywords

HO2+CO; rapid compression; uncertainty analysis; carbon monoxide combustion

Ask authors/readers for more resources

This paper constitutes an experimental and numerical study, using uncertainty analysis of the most important parameters, to evaluate the mechanism for the combustion of CO + H-2, mixtures at high pressures in the range 15-50 bar and temperatures from 950 to 1100 K. Experiments were performed in a rapid compression machine. Autoignition delays were measured for stoichiometric compositions of CO + H-2 containing between 0 and 80% CO in the total fuel mixture. The experimental results showed an unequivocal monotonic increase as the proportion of CO in the mixture was raised. Comparisons were made also with the measured ignition delays in mixtures of H-2 with increasing dilution by N-2, corresponding to the proportions of CO present. These times also increased monotonically, albeit with a greater sensitivity to the extent of dilution than those measured in the CO + H-2 mixtures. By contrast, numerical simulations for the same mixtures, based on a kinetic model derived by Davis et al. displayed a qualitative discrepancy as there was virtually no sensitivity of the ignition delay to the changing ratio of CO + H-2, certainly up to 80% replacement. No exceptions to this trend were found, despite tests being made using seven other kinetic models for CO + H-2 combustion. Global uncertainty analyses were then applied to the Davis et al. model in order to trace the origins of this discrepancy. The analyses took into account the uncertainties in all rate parameters in the model, which is a prerequisite for evaluation against ignition delay data. It is shown that the reaction rate constant recommended by Baulch et al. for the HO2 + CO reaction, at T similar to 1000 K, could be LIP to a factor of 10 too high and that lowering this rate corrected the qualitative anomaly between experiment and numerical prediction. (C) 2006 The Combustion Institute. Published by Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available