4.3 Article

Comparison of the Truview PCD™ and the GlideScope® video laryngoscopes with direct laryngoscopy in pediatric patients: a randomized trial

Journal

Publisher

SPRINGER
DOI: 10.1007/s12630-013-9906-x

Keywords

-

Categories

Funding

  1. Truphatek International Ltd. (Ashland, MO)

Ask authors/readers for more resources

The GlideScope(A (R)) video laryngoscope has a 60A degrees angled blade and the blade of the Truview PCD (TM) video laryngoscope has an optical lens that provides a 46A degrees refraction of the viewing angle. Despite successful results using the GlideScope in adults, few studies have been published regarding its use in pediatric patients. We therefore tested our joint primary hypothesis that the GlideScope and the Truview PCD video laryngoscopes provide superior visualization to direct laryngoscopy and are non-inferior regarding time to intubation. One hundred thirty-four patients (neonate to ten years of age, American Society of Anesthesiologists physical status I-III) scheduled for general surgical procedures were randomized to tracheal intubation using the Truview PCD or GlideScope video laryngoscope or direct laryngoscopy (Macintosh blade). The laryngoscopic view was scored using the Cormack-Lehane scale. Time to intubation (defined as the time from the moment the device entered the patient's mouth until end-tidal CO2 was detected) and the number of attempts were recorded. The Cormack-Lehane views attained using the GlideScope (P > 0.99) and Truview PCD (P = 0.18) were not superior to the views attained with direct laryngoscopy. Furthermore, the view attained using the GlideScope was significantly worse than that attained using direct laryngoscopy (P < 0.001). Fewer patients showed Cormack-Lehane grade I views with the GlideScope than with the Truview PCD (14% vs 82%, respectively; 95% confidence interval [CI] -91% to -46%). The observed median [Q1, Q3] times to intubation were: 39 [31, 59] sec, 44 [28, 62] sec, and 23 [21, 28] sec with the GlideScope, Truview PCD, and direct laryngoscopy, respectively, with median differences of 14 sec (95% CI 7 to 26, GlideScope - direct laryngoscopy) and 17 sec (95% CI 6 to 28, Truview PCD - direct laryngoscopy). The Cormack-Lehane views attained using the GlideScope and the Truview PCD video laryngoscopes were not superior to views attained using direct laryngoscopy. Visualization with the GlideScope was significantly worse than with direct laryngoscopy. Use of the GlideScope and Truview PCD systems should be restricted to patients with specific indications.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available