Characterisation of the cell suspension harvested from the dermal epidermal junction using a ReCell® kit

Journal

BURNS
Volume 38, Issue 1, Pages 44-51

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.burns.2011.03.001

Keywords

ReCell (R); Cells; Burn; Keratinocytes; Melanocytes

Funding

  1. Avita Medical
  2. McComb Foundation

Ask authors/readers for more resources

Background: The use of non-cultured autologous cells to promote wound healing and in reconstructive procedures is increasing. One common method for preparing these cells is the use of the ReCell (R) device. However, despite its current clinical use, no characterisation of the cell suspension produced using a ReCell (R)) device has been published. Objective: To characterise the Re Cell suspension that is applied to wounds for cell type, viability, yield, stability and proliferative potential. Methods: The ReCell (R) device was used to harvest cells from a 2 cm(2) piece of split-thickness skin isolated using a dermatome. The resulting cell suspension was analysed for cell yield, cell type, viability over time, proliferative potential and reproducibility. Results: Average viable cell yield was 1.7 x 10(6)/cm(2) of tissue, with 75.5% of the total cell isolate viable. Total viable cell number was not significantly reduced after 4 h storage at 22 degrees C or 4 degrees C, and was stable for 24 h at 4 degrees C. Proliferative potential was assessed using a colony forming assay, with 0.3% of viable cells isolated forming keratinocyte colonies. Predominantly the suspension contained keratinocytes (64.3 +/- 28.8%) and fibroblasts (30.3 +/- 14.0%), with a small population of melanocytes also identified (3.5 +/- 0.5%). Finally, the supernatant contained low total protein (0.92 mg/ml) and the supernatant had no significant effects on cell viability or growth when applied ex vivo. Conclusions: These results suggest the ReCell (R) device provides a method for the preparation of a cell suspension with high viability and proliferative potential, containing viable melanocytes and no apparent toxic cell debris. Further work on the sustained viability of these cells in vivo, and in particular after application to the wound, will be important to better understand the potential of the ReCell (R) device in the clinic. Crown Copyright (C) 2011 Published by Elsevier Ltd and ISBI. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available